3 changes: 2 additions & 1 deletion scapy/contrib/pnio_rpc.py
Original file line number Diff line number Diff line change
Expand Up @@ -1353,8 +1353,9 @@ class PNIORealTimeAcyclicPDUHeader(Packet):
# IEC-61158-6-10:2021, Table 241
ShortField("AlarmDstEndpoint", 0),
ShortField("AlarmSrcEndpoint", 0),
BitEnumField("PDUTypeType", 0, 4, PDU_TYPE_TYPE),
# PDUType: Version in bits 4-7, Type in bits 0-3
BitEnumField("PDUTypeVersion", 0, 4, PDU_TYPE_VERSION),
BitEnumField("PDUTypeType", 0, 4, PDU_TYPE_TYPE),
BitField("AddFlags", 0, 8),
XShortField("SendSeqNum", 0),
XShortField("AckSeqNum", 0),
Expand Down
6 changes: 6 additions & 0 deletions test/contrib/pnio_rpc.uts
Original file line number Diff line number Diff line change
Expand Up @@ -872,6 +872,12 @@ p = Ether(b'\x00\x11\x22\x33\x44\x55' \
assert p[Alarm_Low].RTA_SDU is None
assert AlarmNotification_Low not in p
assert len(p[Padding].load) == 32
assert p[Alarm_Low].PDUTypeType == 3
assert p[Alarm_Low].PDUTypeVersion == 1

= PNIO Alarm building writes the PDU type in the low nibble
p = Alarm_Low(PDUTypeType=2, PDUTypeVersion=1)
assert raw(p)[4:5] == b'\x12'

= PNIO Alarm building computes VarPartLen
p = Alarm_High(RTA_SDU=AlarmNotification_High(AlarmType=3))