Repository navigation
Feature/show unreliable CGM readings - #832
Open
kristinkand wants to merge 3 commits into
Open
kristinkand wants to merge 3 commits into
kristinkand wants to merge 3 commits into
Conversation
… BG) Companion to Trio's "Show Unreliable G7 Readings" (off by default in Trio): during a sensor issue the Dexcom G7 marks its values unreliable, and Trio, with that setting on, uploads each as an "Unreliable Glucose" treatment, never as an entry. LoopFollow now: - draws them as hollow orange dots at the normal dot size (also with dots turned off); - shows the newest under the BG, in orange with a warning sign, while it is newer than the last reliable reading; - lists them in a tap on the chart after the reliable readings, and shows one in the scrub pill where no reliable reading is. They are never alarmed on, counted in the statistics or used as BG. Without Trio's setting nothing is uploaded and nothing changes in LoopFollow. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01UUzqfqfsM8BQYJ2yoRaLz8
Trio (with "Show Unreliable G7 Readings" on) uploads each G7 reading the sensor marks
unreliable as an "Unreliable Glucose" treatment; the phone already draws
them. The watch now gets them with its state from the phone, or reads
them itself from Nightscout while the phone is away, and shows them as
on the phone: hollow orange dots on the chart and the sparkline, the
newest under the BG ("… not reliable · n min ago") while it is fresh and
newer than the last reliable reading, and in the scrub line where no
reliable reading is. Never used as BG or alarmed on.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UUzqfqfsM8BQYJ2yoRaLz8
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01UUzqfqfsM8BQYJ2yoRaLz8
kristinkand
requested review from
bjorkert,
codebymini and
marionbarker
as code owners
November 11, 2026 15:33
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Needs Trio PR #1762 Trio uploads the CGM readings the sensor marked unreliable as “Unreliable Glucose” treatments. LoopFollow shows them like Trio does, never as BG and never alarmed on:
Phone: hollow orange dots on the chart (tap and scrub show the value), the newest under the BG while it is newer than the last reliable reading
Watch: the dots on the chart and the 2-hour chart, the newest under the BG, and in the scrub line; also when the watch reads Nightscout on its own