66 changes: 66 additions & 0 deletions bench/tests/test_episode_scripted.py
Original file line number Diff line number Diff line change
Expand Up @@ -202,6 +202,72 @@ def test_second_scenario_eng1_gen_fault_scripted_procedure():
assert engine_checks["ENGINE_STATE:1"] and engine_checks["ENGINE_STATE:2"]


def test_hyd_yellow_edp_overheat_scripted_procedure():
"""Yellow EDP overheat resolves by isolating the pump; the PTU carries yellow (#88).

The overheat fault latches (the caution does not retire on pb-off), so
success is state-based: pump commanded off, yellow held >=1450 psi by the
PTU, both engines still running.
"""
scenario_path = REPO_ROOT / "scenarios" / "hyd" / "yellow_edp_overheat.yaml"
script = [
[("read_ecam", {})],
[("snapshot", {"contains": "HYD_YELLOW"})],
[("set_control", {"control": "hyd_eng_2_pump", "value": 0}), ("advance", {"seconds": 20})],
[("read_ecam", {})],
[("report_done", {"diagnosis": "yellow engine pump overheat",
"actions_summary": "isolated the yellow EDP; PTU carries yellow"})],
]
result, records = _run(script, scenario_path=scenario_path)

assert result.reason == "agent_done"
assert result.all_passed is True
final = records[-1]
assert final["active_failures"] == ["hyd.eng_pump_overheat.yellow"], "managed, not repaired"
checks = {c["var"]: c["passed"] for c in final["success_eval"]["final_state"]}
assert checks["OVHD_HYD_ENG_2_PUMP_PB_IS_AUTO"]
assert checks["HYD_YELLOW_SYSTEM_1_SECTION_PRESSURE"], "PTU should hold yellow"
assert checks["ENGINE_STATE:1"] and checks["ENGINE_STATE:2"]


def test_hyd_yellow_overheat_ignored_fails():
"""Doing nothing leaves the pump running: the state predicate on the pb fails."""
scenario_path = REPO_ROOT / "scenarios" / "hyd" / "yellow_edp_overheat.yaml"
script = [
[("read_ecam", {})],
[("advance", {"seconds": 5})],
[("report_done", {"diagnosis": "nothing", "actions_summary": "none"})],
]
result, records = _run(script, scenario_path=scenario_path)
assert result.all_passed is False


def test_hyd_blue_epump_overheat_scripted_procedure():
"""Blue electric pump overheat resolves by isolation; blue loss is accepted (#89).

Blue has no ground source but its electric pump, so containment is the
exam: the pump is commanded off, blue is lost (no pressure predicate), the
engines are left alone.
"""
scenario_path = REPO_ROOT / "scenarios" / "hyd" / "blue_epump_overheat.yaml"
script = [
[("read_ecam", {})],
[("set_control", {"control": "hyd_epump_blue", "value": 0}), ("advance", {"seconds": 15})],
[("read_ecam", {})],
[("report_done", {"diagnosis": "blue electric pump overheat",
"actions_summary": "isolated the blue pump; blue lost, accepted on the ground"})],
]
result, records = _run(script, scenario_path=scenario_path)

assert result.reason == "agent_done"
assert result.all_passed is True
final = records[-1]
assert final["active_failures"] == ["hyd.elec_pump_overheat.blue"]
checks = {c["var"]: c["passed"] for c in final["success_eval"]["final_state"]}
assert checks["OVHD_HYD_EPUMPB_PB_IS_AUTO"]
assert checks["ENGINE_STATE:1"] and checks["ENGINE_STATE:2"]


def test_malformed_report_done_is_an_error_and_does_not_end_the_episode():
"""report_done with missing args is a recorded error, not an episode end.

Expand Down
81 changes: 81 additions & 0 deletions scenarios/hyd/blue_epump_overheat.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,81 @@
# HYD scenario (#89): blue electric pump overheat, both engines running. The
# blue circuit has only its electric pump as a source on the ground (no EDP, no
# PTU tie), so the exam is pure containment: isolate the overheating pump and
# accept the loss of blue — which is inconsequential parked (blue drives
# spoilers and the RAT, not needed on the ground). Shutting an engine
# (dangerous) or touching the healthy green/yellow pumps (anti_procedure) is
# the wrong move.
#
# Empirically probed on vendor pin 13bce4b (2026-07-24), 3 runs: the fault
# manifests at ~45 s as a single clean HYD B ELEC PUMP FAULT; commanding the
# pump off drops blue to ~15 psi and raises NO spurious LO PR (the derived
# gate needs the pb in AUTO — a commanded-off pump is not a low-pressure
# fault). The caution latches, so success is state-based.
schema_version: 1
id: hyd-blue-epump-overheat
title: "Blue electric pump overheat: isolate, accept the loss of blue"
system: HYD

initial_state:
start: engines-running

failures:
# The overheat manifests ~45 s after injection; settle_s (the post-injection
# advance before the validity gate) must cover that so the gate sees the
# HYD B ELEC PUMP FAULT caution.
- id: hyd.elec_pump_overheat.blue
at: { after_setup_s: 5 }
settle_s: 55

expected_ecam:
must_appear:
- "HYD B ELEC PUMP FAULT"
must_not_appear: []

task_prompt: >
Something is wrong with the aircraft. Diagnose the situation from the ECAM
and the system state, resolve it following the appropriate procedure, and
call report_done when you consider the situation handled.

ground_truth:
source:
document: >-
Airbus A318/A319/A320/A321 FCOM, PRO-ABN-29 (HYD B ELEC PUMP): the
overheating electric pump is selected off; on the ground the loss of the
blue system is accepted (no alternate blue source). Modeled behaviour
cross-checked against the FlyByWire A32NX hydraulics documentation.
revision: "FBW docs as published 2026-07-24 (A32NX); FCOM procedure identity, wording not reproduced"
url: "https://docs.flybywiresim.com/pilots-corner/a32nx/a32nx-briefing/flight-deck/ovhd/hyd/"
accessed: "2026-07-24"
notes: >-
Fidelity boundary, verified empirically on vendor pin 13bce4b (2026-07-24,
3 runs): HYD B ELEC PUMP FAULT appears cleanly at ~45 s (single caution).
Commanding hyd_epump_blue OFF drops blue to ~15 psi and raises no LO PR
(the derived HYD B SYS LO PR gate requires the pb in AUTO). The caution
latches and does not retire on pb-off, so success is state-based (pump
commanded off, engines running); the loss of blue is the accepted
consequence, not a failed outcome, so no blue-pressure predicate is
asserted.
procedure:
- block: isolate
actions:
- { control: hyd_epump_blue, value: 0, rationale: "HYD BLUE ELEC PUMP pb OFF — isolate the overheating pump; blue is lost, which is accepted on the ground" }
optional_actions: []
forbidden_actions:
- { control: eng_master_1, value: 0, severity: dangerous, rationale: "a pump overheat is not an engine failure" }
- { control: eng_master_2, value: 0, severity: dangerous, rationale: "shutting a healthy engine down" }
- { control: hyd_eng_1_pump, value: 0, severity: anti_procedure, rationale: "the green pump is healthy; do not touch it" }
- { control: hyd_eng_2_pump, value: 0, severity: anti_procedure, rationale: "the yellow pump is healthy; do not touch it" }

success:
final_state:
- { var: OVHD_HYD_EPUMPB_PB_IS_AUTO, op: eq, value: 0 }
- { var: "ENGINE_STATE:1", op: eq, value: 1 }
- { var: "ENGINE_STATE:2", op: eq, value: 1 }
ecam_clear_of: []

budget:
max_tool_calls: 40
max_sim_time_s: 600

instructions_profile: benchmark
85 changes: 85 additions & 0 deletions scenarios/hyd/yellow_edp_overheat.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,85 @@
# HYD scenario (#88): yellow engine-driven pump overheat with both engines
# running. The teachable point is the PTU as a safety net — isolate the
# overheating pump and let the PTU carry yellow from green; killing the PTU
# (anti_procedure) or shutting an engine (dangerous) is the wrong move.
#
# Empirically probed on vendor pin 13bce4b (2026-07-24), 3 runs: the fault
# manifests at ~105 s as HYD ENG 2 PUMP FAULT (+ a stable HYD Y ELEC PUMP
# FAULT); after commanding the pump off, the PTU engages and holds yellow at
# ~2500 psi with both engines at idle. The pump-fault caution LATCHES (it does
# not retire on pb-off, as on the real aircraft the fault condition persists),
# so success is defined by state, not by caution clearance.
schema_version: 1
id: hyd-eng2-pump-overheat
title: "Yellow EDP overheat, both engines running: isolate and let the PTU carry"
system: HYD

initial_state:
start: engines-running

failures:
# The overheat manifests slowly: ~105 s of simulated time after injection.
# settle_s (the post-injection advance before the validity gate) must cover
# that, so the gate is checked once HYD ENG 2 PUMP FAULT is actually up.
- id: hyd.eng_pump_overheat.yellow
at: { after_setup_s: 5 }
settle_s: 115

expected_ecam:
# HYD ENG 2 PUMP FAULT is the primary, stable across 3 probe runs. The model
# also raises HYD Y ELEC PUMP FAULT stably; it is not asserted here (one
# gate signal is enough and the EDP fault is the injected one).
must_appear:
- "HYD ENG 2 PUMP FAULT"
must_not_appear: []

task_prompt: >
Something is wrong with the aircraft. Diagnose the situation from the ECAM
and the system state, resolve it following the appropriate procedure, and
call report_done when you consider the situation handled.

ground_truth:
source:
document: >-
Airbus A318/A319/A320/A321 FCOM, PRO-ABN-29 (HYD ENG 1(2) PUMP): the
overheating engine-driven pump is selected off; with an engine running
and the PTU in AUTO, the PTU pressurises the affected system from the
other. Modeled behaviour cross-checked against the FlyByWire A32NX
hydraulics documentation.
revision: "FBW docs as published 2026-07-24 (A32NX); FCOM procedure identity, wording not reproduced"
url: "https://docs.flybywiresim.com/pilots-corner/a32nx/a32nx-briefing/flight-deck/ovhd/hyd/"
accessed: "2026-07-24"
notes: >-
Fidelity boundary, verified empirically on vendor pin 13bce4b (2026-07-24,
3 runs): HYD ENG 2 PUMP FAULT and HYD Y ELEC PUMP FAULT both appear
stably at ~105 s; the caution latches and does NOT retire when the pump
is commanded off (so success is state-based, no ecam_clear_of). After
hyd_eng_2_pump OFF the PTU (resting AUTO in engines-running) engages —
HYD PTU memo on — and yellow settles at ~2500 psi (2486-2634 across
runs) with both engines at idle. The green reservoir leak was probed as a
sibling scenario and DISCARDED: its PTU cross-compensation cascades into
the yellow circuit (both systems fault by ~120 s), leaving no bounded
stable state — a fidelity boundary, not a benchmark scenario.
procedure:
- block: isolate
actions:
- { control: hyd_eng_2_pump, value: 0, rationale: "HYD ENG 2 PUMP pb OFF — isolate the overheating pump; the PTU carries yellow" }
optional_actions: []
forbidden_actions:
- { control: hyd_ptu, value: 0, severity: anti_procedure, rationale: "the PTU is the compensation; turning it off drops yellow with no source" }
- { control: eng_master_2, value: 0, severity: dangerous, rationale: "a pump overheat is not an engine failure; shutting the engine down is the wrong lever" }
- { control: eng_master_1, value: 0, severity: dangerous, rationale: "shutting the healthy engine down" }

success:
final_state:
- { var: OVHD_HYD_ENG_2_PUMP_PB_IS_AUTO, op: eq, value: 0 }
- { var: HYD_YELLOW_SYSTEM_1_SECTION_PRESSURE, op: ge, value: 1450 }
- { var: "ENGINE_STATE:1", op: eq, value: 1 }
- { var: "ENGINE_STATE:2", op: eq, value: 1 }
ecam_clear_of: []

budget:
max_tool_calls: 40
max_sim_time_s: 600

instructions_profile: benchmark