Skip to content

fix(gateway): WHO 13 valid MAC, four-digit year, weekday, timezone 100, product firmware log; conformance matrix read form; #Z#C wording (Encyclopedia audit, group 7) - #161

Draft
gdluck wants to merge 5 commits into
OpenWebNet-HA:masterfrom
gdluck:fix/docs-and-who13-lows

Conversation

@gdluck

@gdluck gdluck commented Nov 3, 2026

Copy link
Copy Markdown
Contributor

Requested by A

Summary

Before: a WHO 13 dimension 12 reply with an octet above 255 or with eight values (the ZigBee IEEE address) is formatted as a MAC; a two-digit year is accepted as year 26; the weekday field is never read; timezone code 100 decodes as -00:00; an addressed dimension 16 reply is logged as the gateway's firmware; the conformance matrix shows *#13*0*0## as the read form (refused by all twelve emulated gateways); the device-type docstring does not say that unlisted or shared codes stay unknown; the merged #140 docstring of actuators_status calls #Z#C an actuator form.

After: valid_mac_address (six octets 0..255, else None; eight values logged as the IEEE address) beside the unchanged mac_address MyHOME's identify flow pins; a date needs a four-digit year (date None otherwise, frame still valid, day and month still validated first exactly as on master); weekday 0..6 else None; 100 -> +00:00; the addressed dimension 16 is logged as a product firmware; the matrix shows *#13**0## / *#13**22##; docstrings corrected; #Z#C described as zone Z through 4-zone central unit C. Out-of-table clock values keep raising from OWNMessage.parse and the sessions keep catching them, as settled when #144 was closed.

Context and how it was found. A asked for OWNd master to be checked against the OpenWebNet Encyclopedia functional pages (audit of 2026-10-28; 94 rows reproduced by running the code; confirmed by a firmware-oracle replay on the twelve emulated gateways and a whole-Encyclopedia search). This is the WHO 13 group (rows G2..G10, G1 deliberately not changed) plus the #140 leftover. Oracle: *#13*0*0## refused 12/12, *#13**0## answered 12/12.

Changes

  • OWNd/message/gateway.py (who-13-integration-gateway/dimensions.md "DIMENSION 1", "DIMENSION 12", "DIMENSION 16", zigbee-network-management.md "DIMENSION 12"; capabilities.md "Read form"): valid_mac_address (G2 / G3), _gateway_date (day / month validated first as on master, then the four-digit year, else date None; same for dimension 22) (G4), weekday (G10), 100 -> +00:00 (G7), addressed dimension 16 log (G8; firmware_version still populated), device-type docstring and WHO13_DEVICE_TYPES comment (G9), ASCII-only digit checks in the touched helpers (G12 decision). G1 not changed: out-of-table clock values (124, 0530, hour 25, month 13, empty fields) keep raising, settled by OWNd#144 (closed 2026-10-28): the values are synthetic oracle stimuli, the sessions already catch the ValueError, and a degraded message would let _locked_send put malformed clock writes on the wire and clear MyHOME's unconfigured-timezone repair. G6 (write-frame log wording) dropped: MyHOME's f461_who13_clock_tz_live_2026_10_26 trace test pins the current text.
  • OWNd/message/heating.py: actuators_status docstring: #Z#C is zone Z through a four-zone central unit C (Encyclopedia who-4-temperature-control/addressing.md), not an actuator form (feat(heating): OWNHeatingCommand.actuators_status(where) builder for *#4*WHERE*20## #140 leftover).
  • docs/protocol_conformance_matrix.md (G5): WHO 13 read form *#13**0## / *#13**22##, with the oracle rows.
  • CHANGELOG.md: [Unreleased] ### Changed bullets for the behaviour changes only (no bullet for docs-only edits).

State Diagram

N/A — small decoder additions and documentation; the clock decode path is unchanged.

Where are the traces

Subsystem Capture Plant Frames verified by this PR
WHO 13 identify / clock MyHOME tests/test_config_flow_identify.py, tests/test_f461_who13_clock_tz_live_2026_10_26_trace.py (OpenWebNet-HA/MyHOME#823) F461 2.0.11, MyHomeServer1 3.87.13 mac_address formatting and the clock log texts MyHOME pins are unchanged: MyHOME suite 5187 passed against this branch
WHO 13 read form own-firmware-oracle ownd-audit-frames replay (2026-10-28, emulated) twelve emulated gateways *#13*0*0## refused 12/12, *#13**0## answered 12/12

What does the Oracle say

See the table above (row G5 of the audit).

Testing

  • tests/test_message_protocol.py (new WHO 13 cases: valid MAC range, eight-value address, year / weekday in both validation orders, timezone 100, addressed dimension 16, ASCII digits) and tests/test_message_edges.py unchanged (its pinned-raise tests still hold).
  • Full suite: 2801 passed (plus the environment-dependent test_runtime_version_matches_installed_package); scripts/verify_coverage.py 7,027 / 7,027, branch rate 1.0 on gateway.py and heating.py; ruff check, mypy OWNd, scripts/verify_library_standards.py, scripts/sync_documentation.py --check pass.
  • MyHOME v2-phase1-architecture suite against this branch: 5187 passed, 1 deselected (the pin-bump doc test).

Precedent check

Kept: #144 (clock values keep raising, send-path validation keeps rejecting malformed clock writes, whole-hour timezones only); #129 builders' ValueError on non-whole-hour offsets; MyHOME's identity.py reads raw dimension_value (dim_val[3] / 999 untouched); the #139 decoder untouched. Changed back after running MyHOME's suite and a second-opinion review: mac_address keeps master's formatting (the range-checked value is the new valid_mac_address), the write-frame log text stays, and day / month are validated before the year width.

🤖 Generated with Claude Code

gdluck and others added 5 commits November 3, 2026 09:40
…uators_status

report 21 G5 and the OpenWebNet-HA#140 leftover.

docs/protocol_conformance_matrix.md showed `*OpenWebNet-HA#13*0*0##` / `*OpenWebNet-HA#13*0*22##`
(WHERE 0) as the verified WHO 13 examples. The published read form has an
empty WHERE, `*OpenWebNet-HA#13**DIMENSION##` (Encyclopedia
who-13-integration-gateway/dimensions.md "Read form", capabilities.md
"Command-session behavior"); the review-session oracle run of 2026-11-03
(audit_ency/ORACLE_CONFIRM.md row G5) has `*OpenWebNet-HA#13*0*0##` nack, silent on all
twelve emulated gateways and `*OpenWebNet-HA#13**0##` answered on all twelve, and the
builders (`request_time`, the event keepalive) already emit the empty form.

OWNHeatingCommand.actuators_status called `#Z#N` "an actuator addressed
through the central unit"; per who-4-temperature-control/addressing.md
"Historical central-unit variants" the form is `#Z#C`, zone Z through a
four-zone central unit C. Wording only; the accepted grammar is unchanged.

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
…ekday, tz 100 and log wording

report 21 G2, G3, G4, G6, G7, G8, G9, G10. G1 not changed: settled by
OWNd#144 (closed 2026-10-28), master keeps raising ValueError for
out-of-table clock values and the sessions catch it.

G2 / G3: Dimension 12 decodes six decimal octets in 0..255 only
(Encyclopedia who-13-integration-gateway/dimensions.md "DIMENSION 12 -
MAC address"); an octet above 255 or an eight-value reply (the ZigBee
interface IEEE address, zigbee-network-management.md "DIMENSION 12 -
Interface IEEE address", ENCY_CONFIRM ZB-108) leaves mac_address None
with the values raw in dimension_value.

G4 / G10: a Dimension 1 / 22 year must be four digits (dimensions.md
"DIMENSION 1 - Date"): `*OpenWebNet-HA#13**1*04*15*10*26##` stays a valid message as
on master, with date None instead of 0026-10-15. New `weekday` property,
0..6 from `00..06`, None outside, date unchanged and no calendar
cross-check (the TS10 client writes a fixed `00`, ENCY_CONFIRM G10).

G7: `T` 100 (GMT-0) reads `+00:00` like `000`.

G6: a parsed write frame `*OpenWebNet-HA#13**#0/michnovka#1/OpenWebNet-HA#22*...##` logs "Setting gateway
time/date to: ..." (dimensions.md "Write form": client -> gateway
writes, ENCY_CONFIRM G6); the reply form built by report_* keeps
"broadcasting".

G8: an addressed Dimension 16 reply (`*OpenWebNet-HA#13*123400#9*16*1*2*3##`) logs
"Product 123400#9's firmware version" (zigbee-network-management.md
"DIMENSION 16 and 17", ENCY_CONFIRM ZB-109/110); firmware_version and
where are unchanged.

G9: device_type docstring and the WHO13_DEVICE_TYPES comment say that an
unlisted code stays `Unknown (N)` and that the non-unique 200 is a list
of sharers, not a product identity (capabilities.md "Product
identification", dimensions.md "DIMENSION 15 - Device type").

Tests: tests/test_message_protocol.py (tz 100 and 0530 still raising,
year / weekday, write-frame logs, MAC range, eight-value dimension 12,
addressed dimension 16). The pinned-raise tests of
tests/test_message_edges.py and test_malformed_gateway_clock_is_rejected
are untouched. Golden fixtures unchanged.

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
…nly WHO 13 helpers (decisions D59, D12, D14)

report 21 G2, G3 (precedent gate). MyHOME#804 pins that OWNGatewayEvent.mac_address formats
any six values without a 0..255 range check (tests/test_config_flow_identify.py: an octet 256
reads "100" and the config flow refuses it itself), so mac_address keeps that behaviour and the
range-checked value moves to the new valid_mac_address property (six decimal ASCII octets in
0..255, Encyclopedia who-13-integration-gateway/dimensions.md "DIMENSION 12 - MAC address";
None for the eight-value ZigBee interface IEEE address of zigbee-network-management.md).
_gateway_weekday, _gateway_date and the octet check take ASCII digits only (OWNd#139 rule:
non-ASCII digits never decode). The docs-only CHANGELOG bullet is dropped (OWNd#143: no
CHANGELOG entry when no runtime behaviour changed).

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
…ock writes (MyHOME pin)

report 21 G6 (precedent gate). MyHOME pins the log of the write form *OpenWebNet-HA#13**#0*22*50*00*## as
"Gateway broadcasting internal time: 22:50:00."
(tests/test_f461_who13_clock_tz_live_2026_10_26_trace.py::test_written_strings_fail_before_pass_after),
so the "Setting gateway ... to" wording is not applied to parsed frames; the set_* builders keep
their own "Setting gateway ..." text as on master. CHANGELOG bullet trimmed accordingly.

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
…w follow-up)

report 21 G4. _gateway_date validated day / month only for a four-digit year, so
*OpenWebNet-HA#13**1*04*99*32*26## parsed with date None where master raised on month 99 / day 32
(OWNd#144: out-of-table clock values keep raising inside parse). Day and month are now
validated first exactly as on master (against a leap year, so 29 February passes), for
dimension 1 and dimension 22 on both OWNGatewayEvent and OWNGatewayCommand; only a
well-formed date with a non-four-digit year gives date None (Encyclopedia
who-13-integration-gateway/dimensions.md "DIMENSION 1 - Date"). Tests cover both orders.

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
@codecov-commenter

Copy link
Copy Markdown

⚠️ Please install the 'codecov app svg image' to ensure uploads and comments are reliably processed by Codecov.

Codecov Report

✅ All modified and coverable lines are covered by tests.

📢 Thoughts on this report? Let us know!

This branch has not been deployed

No deployments
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment