Original file line number Diff line number Diff line change
Expand Up @@ -85,6 +85,23 @@ bound, and the first person to rely on that is the one holding a silent outage.

- **The detection delay is unbounded**, and no amount of tuning the cron
changes that. 15 minutes is a ceiling on how often it *could* look.
- **Measured on this watcher, over its first day: 4 ticks against 91 expected,
4.4%.** The window was 2026-10-19 05:30Z to 2026-10-20 04:06Z, the ticks
landed at 11:07, 17:28, 21:42 and 00:42Z, and the gaps between them were
6.4 h, 4.2 h and 3.0 h. Registration lag does not explain it: counting only
from the first tick gives 3 of 67, the same 4.5%. So the real cadence of this
watcher is **roughly one look every 5.7 hours**, not every 15 minutes, and
the worst gap observed so far is 6.4 hours.

This is worse as a ratio than the `cron: "17 * * * *"` sample quoted above
(1 of 9, 11%) and slightly better in absolute terms (one look per 5.7 h
against one per 9 h), which is the only comparison that matters for
detection. **It does not reopen the decision.** The acceptance bar this
watcher was built against is catching a silent outage *the same day*, after
six days of blindness was the original failure; a worst case of 6.4 hours
clears that bar. What it does invalidate is the number a reader infers from
the cron expression, so quote the measured cadence and not `*/15` wherever
this watcher's latency is described.
- **Whether it ran at all is a thing to measure, repeatedly.** The one-line
check above belongs in any review of this watcher; empty output is the
answer, not an error.
Expand Down Expand Up @@ -121,7 +138,12 @@ bound, and the first person to rely on that is the one holding a silent outage.
is three edits, not one — its pager steps hang on `inputs.page`, which
`schedule` does not supply, and it does not set the `PC_ALERT_MAX_AGE_H=0` /
`PC_STILL_RED_WAKE=0` pair above, so a pager wired up naively would mint a
ticket per tick, 96 a day for one outage. Scheduling it *without* a pager was
ticket per tick. That was first written here as 96 a day for one outage,
which is the nominal figure and about 24 times the real one: at the delivery
rate measured above it is nearer 4 a day. The pair is still required, because
the requirement is one ticket per outage and not a tolerable number of them,
but the case for it rests on the rule rather than on the scare figure.
Scheduling it *without* a pager was
considered and rejected: a red run nobody is subscribed to is the appearance
of detection, not detection, and this record already warns against exactly
that trade one bullet up. So the choice is binary — page from inside the LAN,
Expand Down
Loading