diff --git a/docs/EN/DailyLifeWithAaps/TimezoneTraveling-DaylightSavingTime.md b/docs/EN/DailyLifeWithAaps/TimezoneTraveling-DaylightSavingTime.md index fec9db3e2cf2..1e451a8427bd 100644 --- a/docs/EN/DailyLifeWithAaps/TimezoneTraveling-DaylightSavingTime.md +++ b/docs/EN/DailyLifeWithAaps/TimezoneTraveling-DaylightSavingTime.md @@ -82,19 +82,22 @@ When the time zone or time changes running **TBR's** are stopped. (time-adjustment-daylight-savings-time-dst)= ## DAYLIGHT SAVING (DST) -Time adjustment daylight savings time -Depending on your pump and CGM setup, jumps in time can lead to problems with **AAPS** to function correctlyy. -For instance with the Combo pump, the pump history is read twice leading to duplicate entries. For some pumps it is better to make time zone adjustments while awake and not during the night. +Time adjustment for daylight savings time. + +Depending on your pump and CGM setup, jumps in time can lead to problems with **AAPS** to function correctly. +For instance with the Combo pump & DST, the pump history is read twice leading to duplicate entries. For some pumps it is better to make time zone adjustments while awake before DST takes place and not during the night. ### DST automatic adjustment for most pumps * This adjustment feature is available for **AAPS** version 2.2 onwards. -* Howeever, the fully closed Loop will be deactivated for 3 hours AFTER the DST switch (usually 1am onwards) has taken place and **AAPS** will default to background basal as selected in your **Profile**. +* Howeever, the __Loop__ will be deactivated for 3 hours AFTER the DST switch (usually 1am onwards) has taken place and **AAPS** will default to background basal as selected in your **Profile**. + This is done for safety reasons - **IOB** may be too high due to duplicated bolus prior to DST change. -* After DST has taken place, select **Profile Switch** to user's desired **Profile** to enable fully closed Loop. -* You will also receive a notification on **AAPS** main screen prior to DST change that the Fully Closed Loop has been disabled temporarily. This message will appear without beep, vibration or anything.** + +* After DST has taken place, select **Profile Switch** to user's desired **Profile** to enable the __Loop__. +* You will also receive a notification on **AAPS** main screen prior to DST change that the __Loop__ has been disabled temporarily. This message will appear without beep, vibration or similar sound.** If you bolus with **AAPS'** calculator please do not use **COB** and **IOB** data unless you are sure this data is absolutely correct. Take caution and do not use this feature for a couple of hours after DST switch has taken place. @@ -113,7 +116,7 @@ If you bolus with **AAPS'** calculator please do not use **COB** and **IOB** dat * Otherwise, if you do not want **AAPS** to temporarily default to background basal overnight, you can change the time zone the day prior DST is due to take place to avoid overnight disruption. NOTE THIS OPTION MAY CAUSE YOUR POD TO PREMATURELY EXPIRE. PLEASE HAVE SUPPLIES WITH YOU IF OPTING FOR THE FEATURE BELOW. #### Actions to take before the clock change -1. Switch OFF any Phone's settings that automatically sets the Phone's time zone, so the user can change to a time zone that does not use DST. How to enable this will depend on your smartphone and Android version. +1. Switch OFF any Phone's settings that automatically sets the Phone's time zone, so the user can change to a desired time zone that does not use DST. How to enable this will depend on your smartphone and Android version. * Some phones have two settings, one for automatic setting of the time (which ideally should remain on) and one for automatic setting of the time zone (which you must turn OFF). * Unfortunately, some Android versions have a single switch to enable automatic setting of both the time and the timezone. You’ll have to turn this off for now. @@ -133,7 +136,7 @@ If you bolus with **AAPS'** calculator please do not use **COB** and **IOB** dat 3. **AAPS** refresh your pump and switch to your desired **Profile**. -3. Check **AAPS's** **IOB** and **COB** and if this is inaccurate disable the Fully Closed Loop for at least one DIA and Max-Carb-Time - whatever is bigger. +3. Check **AAPS's** **IOB** and **COB** and if this is inaccurate disable the __Loop__ for at least one DIA and Max-Carb-Time - whatever is bigger. 4. Actions to take after the clock change. A good time to make revert to local time zone is with low **IOB**. E.g. an hour before a meal such as breakfast. Ideally your **COB** and **IOB** should both be close to zero. @@ -145,7 +148,7 @@ This section is only valid for the old, Ruffy-based driver. The new driver adjus **AAPS** will issue an alarm if the time between pump and phone differs too much. In case of DST time adjustment, this would be in the middle of the night. To prevent this and enjoy your sleep instead, follow these steps so that you can force the time change at a time convenient to yourself: #### Actions to take before the clock change -1. Switch OFF any setting that automatically sets the timezone, so you can force the time change when you want to. How you can do this will depend on your smartphone and Android version. +1. Switch OFF any setting that automatically sets the timezone, so you can force the time change when you want to. How this is done will depend on your smartphone and Android version. * Some have two settings, one for automatic setting of the time (which ideally should remain on) and one for automatic setting of the timezone (which you must turn OFF). * Unfortunately some Android versions have a single switch to enable automatic setting of both the time and the timezone. You’ll have to turn this off for now. @@ -164,20 +167,20 @@ This section is only valid for the old, Ruffy-based driver. The new driver adjus * DON'T press "delete treatments in the future" * Hit "remove" on all future treatments and duplicate ones. This should invalidate the treatments rather than removing them so they will not be considered for IOB anymore. -5. If the situation on how much IOB/COB is unclear - for safety please disable the loop for at least one DIA and Max-Carb-Time - whatever is bigger.* +5. If the situation on how much IOB/COB is unclear - for safety please disable the __Loop__ for at least one DIA and Max-Carb-Time - whatever is bigger.* -#### Actions to take after the clock change +#### Actions to take after the clock change / DST A good time to make this switch would be with low **IOB**. E.g. an hour before a meal such as breakfast, (any recent boluses in the pump history will have been small SMB corrections. Your **COB** and **IOB** should both be close to zero.) 1. Change the Android timezone back to your current location and re-enable automatic timezone. 2. **AAPS** will soon start alerting you that the Combo’s clock doesn’t match. So update the pump’s clock manually via the pump’s screen and buttons. 3. On the **AAPS** “Combo” screen, press Refresh. -4. Then go to the Treatments screen, and look for any events in the future. There shouldn’t be many. +4. GO Treatments screen, and look for any future events. There shouldn’t be many. - * DON'T press "delete treatments in the future" - * Hit "remove" on all future treatments and duplicate ones. This should invalidate the treatments rather than removing them so they will not be considered for IOB anymore. + * DON'T press "delete Treatments in the future" + * Hit "remove" on all future Treatments and duplicate ones. This should invalidate the Treatments rather than removing them so they will not be considered for __IOB__. -5. If the situation on how much IOB/COB is unclear - for safety please disable the loop for at least one DIA and Max-Carb-Time - whatever is bigger.* +5. If the situation on how much IOB/COB is unclear - for safety please disable the __Loop__ for at least one __DIA__ and Max-Carb-Time - whatever is bigger.* 6. Continue as normal.